Description
Features
S8FS-C02505 :
- Power rating : 25 W
- Output voltage (VDC) : 5 V
- Input :
- Efficiency : 115 VAC input (80% typ.) , 230 VAC input (82% typ.)
- Voltage range :Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DC input is the positive side and safety standards do not apply.)
- Frequency : 50 /60 Hz (47 to 450 Hz)
- Current : 115 VAC input 0.49 A typ. , 230 VAC input 0.3 A typ.
- Leakage current : 115 VAC input (0.10 mA) , 230 VAC input (0.20 mA)
- Inrush current (for a cold start at 25°) : 115 VAC input 16 A typ.
,230 VAC input 32 A typ.
- Output :
- Rated Output Current : 5 A
- Voltage adjustment range : −10% to 10% (with V. ADJ)
- Ripple & Noise voltage (100 to 240 VAC input) : 20 mVp-p max.
- Input variation influence : 0.5% max
- Load variation influence : 1.0% max.
- Temperature variation influence (100 to 240 VAC input) : 0.03%/°C max
- Startup time (115 VAC input) 390 ms typ. , (230 VAC input) 360 ms typ
- Hold time : (115 VAC input) 17 ms typ. , (230 VAC input) 103 ms typ
Overvoltage protection : Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again)
S8FS-C02512 :
- Power rating : 25 W
- Output voltage (VDC) : 12 V
- Input :
- Efficiency : 115 VAC input (84% typ.) , 230 VAC input (86% typ.)
- Voltage range :Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DC input is the positive side and safety standards do not apply.) (Derating is required according to the input voltage. Refer to Derating Curves on page 18.)
- Frequency : 50 /60 Hz (47 to 450 Hz)
- Current : 115 VAC input 0.49 A typ. , 230 VAC input 0.3 A typ.
- Leakage current : 115 VAC input (0.10 mA) , 230 VAC input (0.20 mA)
- Inrush current (for a cold start at 25°) : 115 VAC input 16 A typ.
,230 VAC input 32 A typ. - Output :
- Rated Output Current : 2.1 A
- Voltage adjustment range : −10% to 10% (with V. ADJ)
- Ripple & Noise voltage (100 to 240 VAC input) : 20 mVp-p max.
- Input variation influence : 0.5% max
- Load variation influence : 1.0% max.
- Temperature variation influence (100 to 240 VAC input) : 0.03%/°C max
- Startup time (115 VAC input) 340 ms typ. , (230 VAC input) 350 ms typ
- Hold time : (115 VAC input) 22 ms typ. , (230 VAC input) 113 ms typ
Overvoltage protection : Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again)
S8FS-C02515 :
- Power rating : 25 W
- Output voltage (VDC) : 15 V
- Input :
- Efficiency : 115 VAC input (85% typ.) , 230 VAC input (88% typ.)
- Voltage range :Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DC input is the positive side and safety standards do not apply.) (Derating is required according to the input voltage. Refer to Derating Curves on page 18.)
- Frequency : 50 /60 Hz (47 to 450 Hz)
- Current : 115 VAC input 0.49 A typ. , 230 VAC input 0.3 A typ.
- Leakage current : 115 VAC input (0.10 mA) , 230 VAC input 0.20 mA (0.20 mA)
- Inrush current (for a cold start at 25°) : 115 VAC input 16 A typ.
,230 VAC input 32 A typ.
- Output :
- Rated Output Current : 1.7 A
- Voltage adjustment range : −10% to 10% (with V. ADJ)
- Ripple & Noise voltage (100 to 240 VAC input) : 30 mVp-p max.
- Input variation influence : 0.5% max
- Load variation influence : 1.0% max.
- Temperature variation influence (100 to 240 VAC input) : 0.03%/°C max
- Startup time (115 VAC input) 400 ms typ. , (230 VAC input) 400 ms typ
- Hold time : (115 VAC input) 23 ms typ. , (230 VAC input) 117 ms typ
Overvoltage protection : Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again)
S8FS-C02524 :
- Power rating : 25 W
- Output voltage (VDC) : 24 V
- Input :
- Efficiency : 115 VAC input (86% typ.) , 230 VAC input (88% typ.)
- Voltage range :Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DC input is the positive side and safety standards do not apply.) (Derating is required according to the input voltage. Refer to Derating Curves on page 18.)
- Frequency : 50 /60 Hz (47 to 450 Hz)
- Current : 115 VAC input 0.49 A typ. , 230 VAC input 0.3 A typ.
- Leakage current : 115 VAC input (0.10 mA) , 230 VAC input (0.20 mA)
- Inrush current (for a cold start at 25°) : 115 VAC input 16 A typ.
,230 VAC input 32 A typ.
- Output :
- Rated Output Current : 1.1 A
- Voltage adjustment range : −10% to 10% (with V. ADJ)
- Ripple & Noise voltage (100 to 240 VAC input) : 40 mVp-p max.
- Input variation influence : 0.5% max
- Load variation influence : 1.0% max.
- Temperature variation influence (100 to 240 VAC input) : 0.03%/°C max
- Startup time (115 VAC input) 360 ms typ. , (230 VAC input) 360 ms typ
- Hold time : (115 VAC input) 21 ms typ. , (230 VAC input) 112 ms typ
Overvoltage protection : Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again)
Term and Condition
รับประกันสินค้า : 1 Year