Description
Features
S8FS-C20005 :
- Power rating : 200 W
- Output voltage (VDC) : 5 V
- Input :
- Efficiency : 115 VAC input (81% typ.) , 230 VAC input (81% typ.)
- Voltage range : Single phase 90 to 132 VAC , Single phase 180 to 264 VAC , 254 to 373 VDC Select with the switch. (The L terminal for the DC input is the positive side and safety standards do not apply.)
- Frequency : 50 /60 Hz (47 to 450 Hz)
- Current : 115 VAC input ( 4 A typ. ) , 230 VAC input ( 2.3 A typ. )
- Leakage current : 115 VAC input (0.35 mA) , 230 VAC input (0.60 mA)
- Inrush current (for a cold start at 25°) : 115 VAC input ( 16 A typ.) ,230 VAC input (32 A typ.)
- Output :
- Rated Output Current : 40 A
- Voltage adjustment range : −10% to 10% (with V. ADJ)
- Ripple & Noise voltage (100 to 120 VAC/200 to 240 VAC input ) : 60 mVp-p max.
- Input variation influence : 0.5% max
- Load variation influence : 1.0% max.
- Temperature variation influence (100 to 120 VAC/200 to 240 VAC input) : 0.03%/°C max
- Startup time (115 VAC input) 620 ms typ. , (230 VAC input) 600 ms typ
- Hold time : (115 VAC input) 32 ms typ. , (230 VAC input) 37 ms typ
- Overvoltage protection : Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again)
S8FS-C20012 :
- Power rating : 200 W
- Output voltage (VDC) : 12 V
- Input :
- Efficiency : 115 VAC input (85% typ.) , 230 VAC input (87% typ.)
- Voltage range : Single phase 90 to 132 VAC , Single phase 180 to 264 VAC , 254 to 373 VDC Select with the switch. (The L terminal for the DC input is the positive side and safety standards do not apply.)
- Frequency : 50 /60 Hz (47 to 450 Hz)
- Current : 115 VAC input ( 4 A typ. ) , 230 VAC input ( 2.3 A typ. )
- Leakage current : 115 VAC input (0.25 mA) , 230 VAC input (0.50 mA)
- Inrush current (for a cold start at 25°) : 115 VAC input ( 16 A typ.) ,230 VAC input (32 A typ.)
- Output :
- Rated Output Current : 17 A
- Voltage adjustment range : −10% to 10% (with V. ADJ)
- Ripple & Noise voltage (100 to 120 VAC/200 to 240 VAC input ) : 60 mVp-p max.
- Input variation influence : 0.5% max
- Load variation influence : 1.0% max.
- Temperature variation influence (100 to 120 VAC/200 to 240 VAC input) : 0.03%/°C max
- Startup time (115 VAC input) 630 ms typ. , (230 VAC input) 610 ms typ
- Hold time : (115 VAC input) 30 ms typ. , (230 VAC input) 35 ms typ
- Overvoltage protection : Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again)
S8FS-C20024 :
- Power rating : 200 W
- Output voltage (VDC) : 24 V
- Input :
- Efficiency : 115 VAC input (88% typ.) , 230 VAC input (88% typ.)
- Voltage range : Single phase 90 to 132 VAC , Single phase 180 to 264 VAC , 254 to 373 VDC Select with the switch. (The L terminal for the DC input is the positive side and safety standards do not apply.)
- Frequency : 50 /60 Hz (47 to 450 Hz)
- Current : 115 VAC input ( 4 A typ. ) , 230 VAC input ( 2.3 A typ. )
- Leakage current : 115 VAC input (0.40 mA) , 230 VAC input (0.75 mA)
- Inrush current (for a cold start at 25°) : 115 VAC input ( 16 A typ.) ,230 VAC input (32 A typ.)
- Output :
- Rated Output Current : 8.8 A
- Voltage adjustment range : −10% to 10% (with V. ADJ)
- Ripple & Noise voltage (100 to 120 VAC/200 to 240 VAC input ) : 110 mVp-p max.
- Input variation influence : 0.5% max
- Load variation influence : 1.0% max.
- Temperature variation influence (100 to 120 VAC/200 to 240 VAC input) : 0.03%/°C max
- Startup time (115 VAC input) 580 ms typ. , (230 VAC input) 550 ms typ
- Hold time : (115 VAC input) 38 ms typ. , (230 VAC input) 45 ms typ
- Overvoltage protection : Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again)
S8FS-C20036 :
- Power rating : 200 W
- Output voltage (VDC) : 36 V
- Input :
- Efficiency : 115 VAC input (89% typ.) , 230 VAC input (90% typ.)
- Voltage range : Single phase 90 to 132 VAC , Single phase 180 to 264 VAC , 254 to 373 VDC Select with the switch. (The L terminal for the DC input is the positive side and safety standards do not apply.)
- Frequency : 50 /60 Hz (47 to 450 Hz)
- Current : 115 VAC input ( 4 A typ. ) , 230 VAC input ( 2.3 A typ. )
- Leakage current : 115 VAC input (0.20 mA) , 230 VAC input (0.45 mA)
- Inrush current (for a cold start at 25°) : 115 VAC input ( 16 A typ.) ,230 VAC input (32 A typ.)
- Output :
- Rated Output Current : 5.9 A
- Voltage adjustment range : −10% to 10% (with V. ADJ)
- Ripple & Noise voltage (100 to 120 VAC/200 to 240 VAC input ) : 130 mVp-p max.
- Input variation influence : 0.5% max
- Load variation influence : 1.0% max.
- Temperature variation influence (100 to 120 VAC/200 to 240 VAC input) : 0.03%/°C max
- Startup time (115 VAC input) 630 ms typ. , (230 VAC input) 600 ms typ
- Hold time : (115 VAC input) 30 ms typ. , (230 VAC input) 37 ms typ
- Overvoltage protection : Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again)
S8FS-C20048 :
- Power rating : 200 W
- Output voltage (VDC) : 48 V
- Input :
- Efficiency : 115 VAC input (88% typ.) , 230 VAC input (90% typ.)
- Voltage range : Single phase 90 to 132 VAC , Single phase 180 to 264 VAC , 254 to 373 VDC Select with the switch. (The L terminal for the DC input is the positive side and safety standards do not apply.)
- Frequency : 50 /60 Hz (47 to 450 Hz)
- Current : 115 VAC input ( 4 A typ. ) , 230 VAC input ( 2.3 A typ. )
- Leakage current : 115 VAC input (0.40 mA) , 230 VAC input (0.80 mA)
- Inrush current (for a cold start at 25°) : 115 VAC input ( 16 A typ.) ,230 VAC input (32 A typ.)
- Output :
- Rated Output Current : 4.43 A
- Voltage adjustment range : −10% to 10% (with V. ADJ)
- Ripple & Noise voltage (100 to 120 VAC/200 to 240 VAC input ) : 120 mVp-p max.
- Input variation influence : 0.5% max
- Load variation influence : 1.0% max.
- Temperature variation influence (100 to 120 VAC/200 to 240 VAC input) : 0.03%/°C max
- Startup time (115 VAC input) 620 ms typ. , (230 VAC input) 600 ms typ
- Hold time : (115 VAC input) 31 ms typ. , (230 VAC input) 37 ms typ
- Overvoltage protection : Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again)
Term and Condition
รับประกันสินค้า : 1 Year