S8FS-G01505C Switch Mode Power Supply Superior Basic Performance, 15 W, 5 VDC, direct mounting

OmronSKU: S8FS-G01505C
No reviews

Output voltage: S8FS-G01505C
Price:
Sale price0.00 ฿

Shipping calculated at checkout

Stock:
Re-stocking soon

Description

Features

S8FS-G01505C :

  • Power rating : 15 W
  • Output voltage : 5 VDC
  • Efficiency :
    80 % typ.(at 100 VAC input)
    80 % typ.(at 200 VAC input)
    80 % typ.(at 230 VAC input)
  • Input :
    Rated input voltage : 100 to 240 VAC
    Allowable input voltage variable range : 85 to 264 VAC(Single-phase),80 to 370 VDC
    Frequency : 50/60Hz (47 to 450 Hz)
    Rated input current : 0.32 A typ.(at 100 VAC input), 0.2 A typ.(at 200 VAC input)
    Leakage current : 0.5 mA max.(at 100 VAC input), 1 mA max.(at 200 VAC input)
    Inrush current (cold start at 25 ℃) : 14 A typ.(at 100 VAC input), 28 A typ.(at 200 VAC input)
  • Output :
    Rated output current : 3 A
    Output voltage variable range : -10 to +15 % (With V.ADJ)
    Ripple : 40 mV(p-p) max.
    Static input variation influence : 0.5 % max.
    Static load variation influence : 1.0 % max.
    Ambient temperature variation influence : 0.05 %/℃ max.
    Start up time : 1000 ms max.(at 100 VAC input), 1000 ms max.(at 200 VAC input)
    Hold time : 15 ms typ.(at 100 VAC input), 75 ms typ.(at 200 VAC input)
  • Construction :
    Construction : Covered type
    Connection : Terminal blocks
    Terminal type : Screw terminal
    Cooling fan : Cooling fan No
    Weight (Main) : 250 g max.

S8FS-G01512C :

  • Power rating : 15 W
  • Output voltage : 12 VDC
  • Efficiency :
    84 % typ.(at 100 VAC input)
    84 % typ.(at 200 VAC input)
    84 % typ.(at 230 VAC input)
  • Input :
    Rated input voltage : 100 to 240 VAC
    Allowable input voltage variable range : 85 to 264 VAC(Single-phase)80 to 370 VDC
    Frequency : 50/60Hz (47 to 450 Hz)
    Rated input current : 0.32 A typ.(at 100 VAC input), 0.2 A typ.(at 200 VAC input)
    Leakage current : 0.5 mA max.(at 100 VAC input), 1 mA max.(at 200 VAC input)
    Inrush current (cold start at 25 ℃) : 14 A typ.(at 100 VAC input), 28 A typ.(at 200 VAC input)
  • Output :
    Rated output current : 1.3 A
    Output voltage variable range : -10 to +15 % (With V.ADJ)
    Ripple : 40 mV(p-p) max.
    Static input variation influence : 0.5 % max.
    Static load variation influence : 1.0 % max.
    Ambient temperature variation influence : 0.05 %/℃ max.
    Start up time : 1000 ms max.(at 100 VAC input) , 1000 ms max.(at 200 VAC input)
    Hold time : 14 ms typ.(at 100 VAC input) , 70 ms typ.(at 200 VAC input)
  • Construction
    Construction : Covered type
    Connection : Terminal blocks
    Terminal type : Screw terminal
    Cooling fan : Cooling fan No
    Weight (Main) : 250 g max.

S8FS-G01515C  :

  • Power rating : 15 W
  • Output voltage : 15 VDC
  • Efficiency :
    84 % typ.(at 100 VAC input)
    84 % typ.(at 200 VAC input)
    84 % typ.(at 230 VAC input)
  • Input :
    Rated input voltage : 100 to 240 VAC
    Allowable input voltage variable range : 85 to 264 VAC(Single-phase), 80 to 370 VDC
    Frequency : 50/60Hz (47 to 450 Hz)
    Rated input current : 0.32 A typ.(at 100 VAC input), 0.2 A typ.(at 200 VAC input)
    Leakage current : 0.5 mA max.(at 100 VAC input) , 1 mA max.(at 200 VAC input)
    Inrush current (cold start at 25 ℃) : 14 A typ.(at 100 VAC input), 28 A typ.(at 200 VAC input)
  • Output :
    Rated output current : 1 A
    Output voltage variable range : -10 to +15 % (With V.ADJ)
    Ripple : 40 mV(p-p) max.
    Static input variation influence : 0.5 % max.
    Static load variation influence : 1.0 % max.
    Ambient temperature variation influence : 0.05 %/℃ max.
    Start up time : 1000 ms max.(at 100 VAC input) , 1000 ms max.(at 200 VAC input)
    Hold time : 15 ms typ.(at 100 VAC input) , 75 ms typ.(at 200 VAC input)
  • Construction : 
    Construction : Covered type
    Connection : Terminal blocks
    Terminal type : Screw terminal
    Cooling fan : Cooling fan No
    Weight (Main) : 250 g max.

S8FS-G01524C :

  • Power rating : 15 W
  • Output voltage : 24 VDC
  • Efficiency :
    85 % typ.(at 100 VAC input)
    86 % typ.(at 200 VAC input)
    86 % typ.(at 230 VAC input)
  • Input :
    Rated input voltage : 100 to 240 VAC
    Allowable input voltage variable range : 85 to 264 VAC(Single-phase), 80 to 370 VDC
    Frequency : 50/60Hz (47 to 450 Hz)
    Rated input current : 0.32 A typ.(at 100 VAC input), 0.2 A typ.(at 200 VAC input)
    Leakage current : 0.5 mA max.(at 100 VAC input) , 1 mA max.(at 200 VAC input)
    Inrush current (cold start at 25 ℃) : 14 A typ.(at 100 VAC input), 28 A typ.(at 200 VAC input)
  • Output :
    Rated output current : 0.65 A
    Output voltage variable range : -10 to +15 % (With V.ADJ)
    Ripple : 60 mV(p-p) max.
    Static input variation influence : 0.5 % max.
    Static load variation influence : 1.0 % max.
    Ambient temperature variation influence : 0.05 %/℃ max.
    Start up time : 1000 ms max.(at 100 VAC input) , 1000 ms max.(at 200 VAC input)
    Hold time : 15 ms typ.(at 100 VAC input) , 70 ms typ.(at 200 VAC input)
  • Construction
    Construction : Covered type
    Connection : Terminal blocks
    Terminal type : Screw terminal
    Cooling fan : Cooling fan No
    Weight (Main) : 250 g max.

Note : Do not use the Inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning.

Term and Condition

รับประกันสินค้า : 1 Year

Download

Datasheet
Download

ดูล่าสุด